by Mats Mats

NS NANOSCORED Y90

Model Y90
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy 625, Alloy C276, Titanium
Dimensions DN 1”(25) – DN 8”(200)
Rupture pressure 0.2 – 70 bar g (depending on material and diameter)
Tolerance from +/- 5 % to +/- 20%
Operating temperature From – 196°C up to 600°C
Operating margin 90% – Able to reach 95% depending on the conditions of service
Fragmentation No
Use under valve Yes
Corrosion resistance Very good
Linings Yes
Container HR/A, HR/P, HR/F, HTC
Rupture sensor Electrical, Magnetic, Inductive, Optical
PED Certification [CE STAMP] Available
ATEX EX II 2 GD Certification Available

by Mats Mats

NS NANOSCORED SCR

Model SCR
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy 625, Alloy C276, Titanium
Dimensions DN 1”(25) – DN 36”(900)
Rupture pressure 0,41 bar g (6 psi g)- 137 bar g (2000 psi g) (depending on material and diameter)
KRg 0.48
Tolerance from +/- 5 % to +/- 20%
Operating temperature From – 196°C up to 480°C
Operating margin 90% – Able to reach 95% depending on the conditions of service
Fragmentation No
Use under valve Yes
Corrosion resistance Very good
Linings Yes
Container HR/A, HR/P, HR/F, HTC
Rupture sensor Electrical, Magnetic, Inductive, Optical
ASME Certification [UD STAMP] Available
PED Certification [CE STAMP] Available
ATEX EX II 2 GD Certification Available

by Mats Mats

NS NANOSCORED SCD

Model SCD
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy 625, Alloy C276, Titanium
Dimensions DN 1”(25) – DN 36”(900)
Rupture pressure 2 bar g (30 psi g) – 413 bar g (6000 psi g) (depending on material and diameter)
KRgl 1.33
Tolerance from +/- 5 % to +/- 20%
Operating temperature From – 196°C up to 600°C
Operating margin up to 85%
Fragmentation No
Use under valve Yes
Corrosion resistance Very good
Linings Yes
Container HI/A, HI/P, HI/F, HTC
Rupture sensor Electrical, Magnetic, Inductive, Optical
ASME Certification [UD STAMP] Available
PED Certification [CE STAMP] Available
ATEX EX II 2 GD Certification Available

by Mats Mats

NS NANOSCORED KRD

Model KRD
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy 625, Alloy C276, Titanium
Dimensions DN 1”(25) – DN 36”(900)
Rupture pressure 0,41 bar g (6 psi g)- 137 bar g (2000 psi g) (depending on material and diameter)
Kr l 0.48
Tolerance from +/- 5 % to +/- 20%
Operating temperature From – 196°C up to 480°C
Operating margin 90% – Able to reach 95% depending on the conditions of service
Fragmentation No
Use under valve Yes
Corrosion resistance Very good
Linings Yes
Container HR/A, HR/P, HR/F, HTC
Rupture sensor Electrical, Magnetic, Inductive, Optical
ASME Certification [UD STAMP] Available
PED Certification [CE STAMP] Available
ATEX EX II 2 GD Certification Available

by

OPTIC FIBRE RUPTURE INDICATORS, OFI 04 and OFI 07

Technical optical fibre properties

Model OFI 04 OFI 07
Optical fibre Plastic Glass with steel protection
Operating temperature From -55 to +70°C/+105°C From -40°C to +250°C
Minimum bending radius R25 R23

Technical amplifier properties

Model OFI 04 OFI 07
Amplifier supply power 12-24 VDC
Amplifier consumption 45 mA max
Operating temperature From -10°C to +60°C
Feedback time 1 msec
Degree of protection IP64
Amplifier material ABS
Rupture disk DCD, DIF, LPD, SCD, SCR, Y90, KRD

by

INDUCTIVE RUPTURE INDICATORS, NAM 05

Model NAM 05
Storage temperature From -40°C to +100°C
Nominal supply voltage 8.2 V
Cable 2 m in PVC
Degree of protection IP 66/67
Rupture disk DCD, DIF, LPD, SCD, SCR, Y90, KRD
Explosion venting panels PS/C, PS/R

by

MAGNETIC RUPTURE INDICATORS NAM03/HT

Model NAM 03/HT
Storage temperature From -40°C to +200°C in accordance with ATEX certification
Material in contact with process fluid Same as disc and disc holder
Max switching voltage 60 VDC
Max switching current 0,4 A
Cable 2 x 0.2 mm2,ø 3.4 mm, 200°C, Class C2
Degree of protection IP 67
Rupture disk DCD, DIF, LPD, SCD, SCR, Y90, KRD

by

ELECTRIC RUPTURE INDICATORS IRC

Model IRC
Operating temperature From -20°C to +260°C (depending on the seal used)
Encapsulating membrane Polyimide (Kapton®)
Printed Circuit Copper
Max supply voltage 24 V DC
Max supply current 50 mA
Cable Standard, 2 m
Rupture disk DCD, SCD, SCR, Y90, KRD

by

ELECTRIC RUPTURE INDICATORS IRE

Model IRE
Operating temperature: From -20°C up to +265°C (depending on the seal used)
Encapsulating membrane: Polyimide (Kapton®)
Printed Circuit: Copper
Max supply voltage: 24 V DC
Max supply current: 50 mA
Cable: Standard, 2 m
Rupture disk: DCD, DIF, LPD, SCD, SCR, Y90, KRD, GM, GA, GR

by

ELECTRIC RUPTURE INDICATORS IRP

Model IRP
Operating temperature: From -20°C to +300°C
Encapsulating membrane: Polyimide (Kapton®)
Printed Circuit Copper:
Max supply voltage: 24 V DC
Max supply current: 50 mA
Cable: Standard, 2 m
Explosion venting panels: PS/C, PS/R