by Mats Mats

SV 32 direct solenoid valve

SV32
3/2 way solenoid valves are available as single station units and they are designed
for use with compressed air, mainly applied where on/ off control
is required with pneumatic actuators.

MATERIAL: Alluminium alloy
SIZES AND CONNECTIONS: Female threaded, ISO 7 Rp 1/4”
MAX. OPERATING PRESSURE: 8 bar
SUPPLY VOLTAGES: 220 V AC, 110 V AC, 24 V DC, 24 V AC
IP RATING: IP 65

by Mats Mats

BCS-220 blowdown controller

BCS220
The ADCATrol BCS220 is a blowdown controller specially designed for use with steam boilers.
The device takes care of both TDS and intermittent blowdown controls. TDS (Total Dissolved Solids)
is controlled through measurement of the boiler water electrical conductivity and intermittent
control is performed via a blowdown timer. The device utilizes a clear multifunction LCD to display
measured conductivity, temperature, operational alarm status and provide an intuitive user interface.
The device is IP 66 rated NEMA 4X and can be panel, surface/wall and pipe mounted.

SUPPLY VOLTAGES:
BCS220 – 90 to 265 V AC
BCS220-LV – 12 to 30 V DC
DIMENSIONS: 150 x 161 x 119
IP RATING: IP 66 NEMA 4X

by Mats Mats

TZIDC, IP 65 (IP 66 on request) NEMA 4X

TZIDC
The ADCATrol TZIDC is an electronically configurable positioner with communication capabilities designed for mounting to pneumatic linear or rotary actuators. It features a small and compact design, a modular construction, and an excellent cost-performance ratio. Fully automatic determination of the control parameters and adaptation to the final control element yield considerable time savings and optimal control behavior.

IP RATING: IP 65 (IP 66 on request) NEMA 4X
AVAILABLE APPROVALS: ATEX, SIL3, FM, CSA, GOST and IECEx
COMMUNICATION:
4 to 20 mA,
HART, Profibus PA or
FOUNDATION Fieldbus-H1
OPERATING TEMPERATURE: -40 to 85 ºC

by Mats Mats

PP981, IP 54 (IP 65 on request) AVAILABLE APPROVALS ATEX

PP981
The ADCATROL PP 981 positioner requires an input signal of 0,2÷1bar (3÷15psi) for the proportional control actuator. The positioner compares the output signal from a controller with the position feedback and varies a pneumatic output signal to the actuator accordingly. The actuator position is therefore guaranteed for any controller output signal and the effects of varying differential pressure.

IP RATING: IP 54 (IP 65 on request)
AVAILABLE APPROVALS: ATEX
COMMUNICATION: 0,2 to 1 bar (3 to 15 psi)
OPERATING TEMPERATURE: -40 to 80 ºC

by Mats Mats

PI991,IP 66 NEMA 4X AVAILABLE APPROVALS ATEX, SIL3, FM, CSA and IECEx

PI991
The microprocessor-controlled positioner PI991 is designed to control pneumatic valve actuators and can be operated locally or by means of control systems. The advanced diagnostic can be partially shown on the local LCD of the positioner or fully on a PC or a DCS workstation with a DTM based software (VALcare or Valve Monitor). The positioner is available with different communication protocols.

IP RATING: IP 66 NEMA 4X
AVAILABLE APPROVALS: ATEX, SIL3, FM, CSA and IECEx
COMMUNICATION: 4 to 20 mA,
HART, Profibus PA, Foxcom or FOUNDATION Fieldbus-H1
OPERATING TEMPERATURE: -40 to 80 ºC

by Mats Mats

PC 25, IP 65 INPUT 4 to 20 mA

PC25
An instrument that converts a standard DC signal to a standard pneumatic signal, for the change-over from electrical controllers to pneumatic control valves, or from electrical measuring system to pneumatic controllers.

IP RATING: IP 65
INPUT: 4 to 20 mA
OUTPUT:
0,2 to 1 bar (3 to 15 psi)
0,4 to 1,2 bar (6 to 18 psi)
OPERATING TEMPERATURE: -40 to 85 ºC

by Mats Mats

TRPT1, Male thread ISO 7/1 Rp (BS21) – 1/2”

TRPT1
The TRPT1 Pt100 resistance temperature sensors are specially designed for general industrial use. The sensing element is an RTD three wire device according to EN 60751 Class A.

SIZES AND CONNECTIONS: Male thread ISO 7/1 Rp (BS21) – 1/2”
IP RATING: IP 66 (KNE enclosure)
OUTPUT: 3-wire RTD or 4 to 20 mA (2-wire)

by Mats Mats

SPS-21, Male threaded ISO 7 R 1/2”

SPS-21
The ADCATROL SPS-21 conductivity probe is used to measure the conductivity (TDS) of the superheated water of boilers or condensate. The probe is used in conjunction with an ADCATROL BCS-211 controller and VPC series blowdown valve.

SIZES AND CONNECTIONS: Male threaded ISO 7 R 1/2”
MAX. OPERATING PRESSURE: 32 bar
MAX. OPERATING TEMPERATURE: 239 ºC
IP RATING: IP 65

by Mats Mats

SPS-33 Male threaded ISO 7 R 1/2”

SPS-33
The ADCATROL SPS-33 conductivity probe is used to measure the conductivity (TDS) of the superheated water of boilers or condensate. The probe is used in conjunction with an ADCATROL BCS-211 controller and VPC series blowdown valve.

SIZES AND CONNECTIONS: Male threaded ISO 7 R 1/2”
MAX. OPERATING PRESSURE: 32 bar
MAX. OPERATING TEMPERATURE: 239 ºC
IP RATING: IP 65

by Mats Mats

PCS1, Male threaded ISO 228 G 1/4”

PCS1
The PCS1 series pressure transmitters are suitable for all industrial applications, specially in severe conditions where high temperatures, pressure peaks and high levels of shock and vibrations are present. They are extremely robust and reliable, thanks to their state of the art SMD electronics and compact all stainless steel construction.

SIZES AND CONNECTIONS: Male threaded,ISO 228 G 1/4”
PRESSURE RANGES:
0 to 6 / 0 to 10 / 0 to 16
0 to 25 / 0 to 40 / 0 to 100
0 to 250 / 0 to 400 / 0 to 600
ACCURACY: < ±0,5% FS
RESPONSE TIME: < 1 ms
IP RATING: IP 65 / IP 67
OUTPUT: 4 to 20 mA (2-wire)