ULTRA LOW PRESSURE LPD
Model LPD
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy 625, Alloy C276, Titanium
Membrane PTFE, PFA
Dimensions DN 2\”(50) – DN 20”(500)
Rupture pressure 5 – 500 millibar g (depending on material and diameter)
Tolerance from +/- 5 % to +/- 20%
Operating temperature up to 265 °C
Operating margin up to 60%
Vacuum support Available
Fragmentation No (membrane only)
Use under valve Yes
Corrosion resistance Good – can be protected with a PTFE membrane
Linings Yes
Container Mounted between flanges
Rupture sensor Electrical, Magnetic, Inductive, Optical
ATEX EX II 2 GD Certification Available