by Mats Mats

ULTRA LOW PRESSURE DIF

Model DIF
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy 625, Alloy C276, Titanium
Membrane PTFE, PFA, Stainless steel, Aluminium
Dimensions DN 2”(15) – DN 40”(1000)
Rupture pressure 0.5 – 5 bar g (depending on material and diameter)
Tolerance from +/- 5 % to +/- 20%
Operating temperature membrane in PTFE/PFA max 265°C, up to 480°C (depending on the membrane)
Operating margin up to 70%
Vacuum support Available
Fragmentation No (membrane only)
Use under valve Yes
Corrosion resistance Good – can be protected with a PTFE membrane
Linings Yes
Container Mounted between flanges
Rupture sensor Electrical, Magnetic, Inductive, Optical
PED Certification [CE STAMP] Available
ATEX EX II 2 GD Certification Available