by

OPTIC FIBRE RUPTURE INDICATORS, OFI 04 and OFI 07

Technical optical fibre properties

Model OFI 04 OFI 07
Optical fibre Plastic Glass with steel protection
Operating temperature From -55 to +70°C/+105°C From -40°C to +250°C
Minimum bending radius R25 R23

Technical amplifier properties

Model OFI 04 OFI 07
Amplifier supply power 12-24 VDC
Amplifier consumption 45 mA max
Operating temperature From -10°C to +60°C
Feedback time 1 msec
Degree of protection IP64
Amplifier material ABS
Rupture disk DCD, DIF, LPD, SCD, SCR, Y90, KRD

by

INDUCTIVE RUPTURE INDICATORS, NAM 05

Model NAM 05
Storage temperature From -40°C to +100°C
Nominal supply voltage 8.2 V
Cable 2 m in PVC
Degree of protection IP 66/67
Rupture disk DCD, DIF, LPD, SCD, SCR, Y90, KRD
Explosion venting panels PS/C, PS/R

by

MAGNETIC RUPTURE INDICATORS NAM03/HT

Model NAM 03/HT
Storage temperature From -40°C to +200°C in accordance with ATEX certification
Material in contact with process fluid Same as disc and disc holder
Max switching voltage 60 VDC
Max switching current 0,4 A
Cable 2 x 0.2 mm2,ø 3.4 mm, 200°C, Class C2
Degree of protection IP 67
Rupture disk DCD, DIF, LPD, SCD, SCR, Y90, KRD

by

ELECTRIC RUPTURE INDICATORS IRC

Model IRC
Operating temperature From -20°C to +260°C (depending on the seal used)
Encapsulating membrane Polyimide (Kapton®)
Printed Circuit Copper
Max supply voltage 24 V DC
Max supply current 50 mA
Cable Standard, 2 m
Rupture disk DCD, SCD, SCR, Y90, KRD

by

ELECTRIC RUPTURE INDICATORS IRE

Model IRE
Operating temperature: From -20°C up to +265°C (depending on the seal used)
Encapsulating membrane: Polyimide (Kapton®)
Printed Circuit: Copper
Max supply voltage: 24 V DC
Max supply current: 50 mA
Cable: Standard, 2 m
Rupture disk: DCD, DIF, LPD, SCD, SCR, Y90, KRD, GM, GA, GR

by

ELECTRIC RUPTURE INDICATORS IRP

Model IRP
Operating temperature: From -20°C to +300°C
Encapsulating membrane: Polyimide (Kapton®)
Printed Circuit Copper:
Max supply voltage: 24 V DC
Max supply current: 50 mA
Cable: Standard, 2 m
Explosion venting panels: PS/C, PS/R

by

ELECTRIC RUPTURE INDICATORS IRL

Model IRL
Operating temperature: From -20°C up to +265°C (depending on the seal used)
Encapsulating membrane: Polyimide (Kapton®)
Printed Circuit: Copper
Max supply voltage: Copper
Max supply current: 50 mA
Cable: Standard, 2 m
Rupture disk: DCD, DIF, LPD, SCD, SCR, Y90, KRD, GM, GA, GR

by

ELECTRIC RUPTURE INDICATORS IRA

Model IRA
Operating temperature: From -20°C up to +300°C
Encapsulating membrane: Polyimide (Kapton®)
Printed Circuit: Copper
Max supply voltage: 24 V DC
Max supply current: 50 mA
Cable: Standard, 2 m
Rupture disk: DCD, DIF, LPD, SCD, SCR, Y90, KRD, GM, GA, GR