Model SCD
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy C276, Titanium, Tantalum
Gaskets PTFE
Dimensions DN 1”(25) – DN 8”(200)
Rupture pressure 3 bar g – 25 bar g (depending on material and diameter)
Tolerance from +/- 5 % to +/- 20%
Operating temperature Gaskets in PTFE (max 265°C)
Operating margin up to 85%
Fragmentation No
Use under valve Yes
Corrosion resistance Very good
Linings Yes
Container HTC
Rupture indicators Electric
ATEX EX II 2 GD Certification Available
PED Certification [CE STAMP] Available
3-A Compliance Available
Model SCD
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy 625, Alloy C276, Titanium
Dimensions DN 1”(25) – DN 36”(900)
Rupture pressure 2 bar g (30 psi g) – 413 bar g (6000 psi g) (depending on material and diameter)
KRgl 1.33
Tolerance from +/- 5 % to +/- 20%
Operating temperature From – 196°C up to 600°C
Operating margin up to 85%
Fragmentation No
Use under valve Yes
Corrosion resistance Very good
Linings Yes
Container HI/A, HI/P, HI/F, HTC
Rupture sensor Electrical, Magnetic, Inductive, Optical
ASME Certification [UD STAMP] Available
PED Certification [CE STAMP] Available
ATEX EX II 2 GD Certification Available
Model SCR
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy 625, Alloy C276, Titanium
Dimensions DN 1”(25) – DN 36”(900)
Rupture pressure 0,41 bar g (6 psi g)- 137 bar g (2000 psi g) (depending on material and diameter)
KRg 0.48
Tolerance from +/- 5 % to +/- 20%
Operating temperature From – 196°C up to 480°C
Operating margin 90% – Able to reach 95% depending on the conditions of service
Fragmentation No
Use under valve Yes
Corrosion resistance Very good
Linings Yes
Container HR/A, HR/P, HR/F, HTC
Rupture sensor Electrical, Magnetic, Inductive, Optical
ASME Certification [UD STAMP] Available
PED Certification [CE STAMP] Available
ATEX EX II 2 GD Certification Available
Model SCR
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy C276, Titanium, Tantalum
Gaskets PTFE
Dimensions DN 1”(25) – DN 8”(200)
Rupture pressure 0,3 bar g – 10 bar g (depending on material and diameter)
Tolerance from +/- 5 % to +/- 20%
Operating temperature Gaskets in PTFE (max 265°C)
Operating margin 90% – Able to reach 95% depending on the conditions of service
Fragmentation No
Use under valve Yes
Corrosion resistance Very good
Linings Yes
Container HTC
Rupture indicators Electric
ATEX EX II 2 GD Certification Available
PED Certification [CE STAMP] Available
3-A Compliance Available
Model SCR
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy 625, Alloy C276, Titanium
Dimensions DN 1”(25) – DN 36”(900)
Rupture pressure 0,41 bar g (6 psi g)- 137 bar g (2000 psi g) (depending on material and diameter)
KRg 0.48
Tolerance from +/- 5 % to +/- 20%
Operating temperature From – 196°C up to 480°C
Operating margin 90% – Able to reach 95% depending on the conditions of service
Fragmentation No
Use under valve Yes
Corrosion resistance Very good
Linings Yes
Container HR/A, HR/P, HR/F, HTC
Rupture sensor Electrical, Magnetic, Inductive, Optical
ASME Certification [UD STAMP] Available
PED Certification [CE STAMP] Available
ATEX EX II 2 GD Certification Available
Model Y90
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy 625, Alloy C276, Titanium
Dimensions DN 1”(25) – DN 8”(200)
Rupture pressure 0.2 – 70 bar g (depending on material and diameter)
Tolerance from +/- 5 % to +/- 20%
Operating temperature From – 196°C up to 600°C
Operating margin 90% – Able to reach 95% depending on the conditions of service
Fragmentation No
Use under valve Yes
Corrosion resistance Very good
Linings Yes
Container HR/A, HR/P, HR/F, HTC
Rupture sensor Electrical, Magnetic, Inductive, Optical
PED Certification [CE STAMP] Available
ATEX EX II 2 GD Certification Available
Model Y90
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy C276, Titanium, Tantalum
Gaskets PTFE
Dimensions DN 1”(25) – DN 8”(800)
Rupture pressure 0,3 bar g – 10 bar g (depending on material and diameter)
Tolerance from +/- 5 % to +/- 20%
Operating temperature Gaskets in PTFE (max 265°C)
Operating margin 90% – Able to reach 95% depending on the conditions of service
Fragmentation No
Use under valve Yes
Corrosion resistance Very good
Linings Yes
Container HTC
Rupture indicators Electric
ATEX EX II 2 GD Certification Available
PED Certification [CE STAMP] Available
3-A Compliance Available
Model Y90
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy 625, Alloy C276, Titanium
Dimensions DN 1”(25) – DN 8”(200)
Rupture pressure 0.2 – 70 bar g (depending on material and diameter)
Tolerance from +/- 5 % to +/- 20%
Operating temperature From – 196°C up to 600°C
Operating margin 90% – Able to reach 95% depending on the conditions of service
Fragmentation No
Use under valve Yes
Corrosion resistance Very good
Linings Yes
Container HR/A, HR/P, HR/F, HTC
Rupture sensor Electrical, Magnetic, Inductive, Optical
PED Certification [CE STAMP] Available
ATEX EX II 2 GD Certification Available
Model KRD
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy C276, Titanium, Tantalum
Gaskets PTFE
Dimensions DN 1”(25) – DN 8”(800)
Rupture pressure 0,3 bar g – 10 bar g (depending on material and diameter)
Tolerance from +/- 5 % to +/- 20%
Operating temperature Gaskets in PTFE (max 265°C)
Operating margin 90% – Able to reach 95% depending on the conditions of service
Fragmentation No
Use under valve Yes
Corrosion resistance Very good
Linings Yes
Container HTC
Rupture indicators Electric
ATEX EX II 2 GD Certification Available
PED Certification [CE STAMP] Available
3-A Compliance Available
Model KRD
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy 625, Alloy C276, Titanium
Dimensions DN 1”(25) – DN 36”(900)
Rupture pressure 0,41 bar g (6 psi g)- 137 bar g (2000 psi g) (depending on material and diameter)
Kr l 0.48
Tolerance from +/- 5 % to +/- 20%
Operating temperature From – 196°C up to 480°C
Operating margin 90% – Able to reach 95% depending on the conditions of service
Fragmentation No
Use under valve Yes
Corrosion resistance Very good
Linings Yes
Container HR/A, HR/P, HR/F, HTC
Rupture sensor Electrical, Magnetic, Inductive, Optical
ASME Certification [UD STAMP] Available
PED Certification [CE STAMP] Available
ATEX EX II 2 GD Certification Available
Model DCD
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy C276, Titanium, Tantalum
Gaskets PTFE
Dimensions DN 1”(25) – DN 8”(800)
Rupture pressure 0,1 bar g – 7 bar g (depending on material and diameter)
Tolerance from +/- 5 % to +/- 20%
Operating temperature Gaskets in PTFE (max 265°C)
Operating margin up to 80%
Fragmentation No
Use under valve Yes
Corrosion resistance Very good
Linings Yes
Container HTC
Rupture indicators Electric
ATEX EX II 2 GD Certification Available
PED Certification [CE STAMP] Available
3-A Compliance Available
Model DCD
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy 625, Alloy C276, Titanium
Membrane PTFE, PFA, Stainless steel, Aluminium
Dimensions DN ½”(15) – DN 40”(1000)
Rupture pressure 0.01 – 110 bar g (depending on material and diameter)
Tolerance from +/- 5 % to +/- 20%
Operating temperature membrane in PTFE/PFA max 265°C, up to 480°C (depending on the membrane)
Operating margin up to 80%
Vacuum support Available
Fragmentation No (membrane only)
Use under valve Yes
Corrosion resistance Good – can be protected with a PTFE membrane
Linings Yes
Container HI/A, HI/P, HI/F, HTC
Rupture sensor Electrical, Magnetic, Inductive, Optical
PED Certification [CE STAMP] Available
ATEX EX II 2 GD Certification Available
Model DIF
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy 625, Alloy C276, Titanium
Membrane PTFE, PFA, Stainless steel, Aluminium
Dimensions DN 2”(15) – DN 40”(1000)
Rupture pressure 0.5 – 5 bar g (depending on material and diameter)
Tolerance from +/- 5 % to +/- 20%
Operating temperature membrane in PTFE/PFA max 265°C, up to 480°C (depending on the membrane)
Operating margin up to 70%
Vacuum support Available
Fragmentation No (membrane only)
Use under valve Yes
Corrosion resistance Good – can be protected with a PTFE membrane
Linings Yes
Container Mounted between flanges
Rupture sensor Electrical, Magnetic, Inductive, Optical
PED Certification [CE STAMP] Available
ATEX EX II 2 GD Certification Available
Model DIF
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy 625, Alloy C276, Titanium
Membrane PTFE, PFA, Stainless steel, Aluminium
Dimensions DN 2”(15) – DN 40”(1000)
Rupture pressure 0.5 – 5 bar g (depending on material and diameter)
Tolerance from +/- 5 % to +/- 20%
Operating temperature membrane in PTFE/PFA max 265°C, up to 480°C (depending on the membrane)
Operating margin up to 70%
Vacuum support Available
Fragmentation No (membrane only)
Use under valve Yes
Corrosion resistance Good – can be protected with a PTFE membrane
Linings Yes
Container Mounted between flanges
Rupture sensor Electrical, Magnetic, Inductive, Optical
PED Certification [CE STAMP] Available
ATEX EX II 2 GD Certification Available
Model DIF
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy 625, Alloy C276, Titanium
Membrane PTFE, PFA, Stainless steel, Aluminium
Dimensions DN 2”(15) – DN 40”(1000)
Rupture pressure 0.5 – 5 bar g (depending on material and diameter)
Tolerance from +/- 5 % to +/- 20%
Operating temperature membrane in PTFE/PFA max 265°C, up to 480°C (depending on the membrane)
Operating margin up to 70%
Vacuum support Available
Fragmentation No (membrane only)
Use under valve Yes
Corrosion resistance Good – can be protected with a PTFE membrane
Linings Yes
Container Mounted between flanges
Rupture sensor Electrical, Magnetic, Inductive, Optical
PED Certification [CE STAMP] Available
ATEX EX II 2 GD Certification Available
Model LPD
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy 625, Alloy C276, Titanium
Membrane PTFE, PFA
Dimensions DN 2\”(50) – DN 20”(500)
Rupture pressure 5 – 500 millibar g (depending on material and diameter)
Tolerance from +/- 5 % to +/- 20%
Operating temperature up to 265 °C
Operating margin up to 60%
Vacuum support Available
Fragmentation No (membrane only)
Use under valve Yes
Corrosion resistance Good – can be protected with a PTFE membrane
Linings Yes
Container Mounted between flanges
Rupture sensor Electrical, Magnetic, Inductive, Optical
ATEX EX II 2 GD Certification Available
Model LPD
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy 625, Alloy C276, Titanium
Membrane PTFE, PFA
Dimensions DN 2\”(50) – DN 20”(500)
Rupture pressure 5 – 500 millibar g (depending on material and diameter)
Tolerance from +/- 5 % to +/- 20%
Operating temperature up to 265 °C
Operating margin up to 60%
Vacuum support Available
Fragmentation No (membrane only)
Use under valve Yes
Corrosion resistance Good – can be protected with a PTFE membrane
Linings Yes
Container Mounted between flanges
Rupture sensor Electrical, Magnetic, Inductive, Optical
ATEX EX II 2 GD Certification Available
Model LPD
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy 625, Alloy C276, Titanium
Membrane PTFE, PFA
Dimensions DN 2\”(50) – DN 20”(500)
Rupture pressure 5 – 500 millibar g (depending on material and diameter)
Tolerance from +/- 5 % to +/- 20%
Operating temperature up to 265 °C
Operating margin up to 60%
Vacuum support Available
Fragmentation No (membrane only)
Use under valve Yes
Corrosion resistance Good – can be protected with a PTFE membrane
Linings Yes
Container Mounted between flanges
Rupture sensor Electrical, Magnetic, Inductive, Optical
ATEX EX II 2 GD Certification Available
Model TCD
Materials Stainless steel
Membrane PTFE, PFA
Dimensions DN 2\”(50) – DN 2\”1/2(65) – DN 3\”(80)
Rupture pressure from 3 to 5 bar g
Tolerance +/- 5 %
Operating temperature up to 265 °C
Operating margin up to 80%
Vacuum support Available
Fragmentation No (membrane only)
Use under valve Yes
Corrosion resistance Good – can be protected with a PTFE membrane
Linings Yes
Container Directly mounted
Rupture sensor Electrical, Magnetic, Inductive, Optical
PED Certification [CE STAMP] Available
ATEX EX II 2 GD Certification Available
Model STD
Materials Stainless steel, Alloy 201, Alloy 400, Alloy 600, Alloy 625, Alloy C276, Titanium
Dimensions DN ½”(15) – DN 24”(600)
Rupture pressure 5 – 1150 bar g (depending on diameter)
Tolerance from +/- 5 % to +/- 20%
Operating temperature up to 600 °C
Operating margin up to 70%
Fragmentation Yes
Use under valve No
Corrosion resistance Very good
Linings Yes
Container SU/M, SU/T, HI/A, HI/P, HI/F
PED Certification [CE STAMP] Available
Explosions: in industrial plants, a real and destructive danger, against which it is essential to find protection. Explosion venting panels are the ideal product for the job.
There are several possible applications and situations, in industrial plants, where it is necessary to protect the structure against a very concrete risk of explosion, usually due to the nature of the products being processed. Explosion venting panels are often the ideal solution to implement a measure of safety in points where this issue is critical, since they are built to yield against pressure as it rises, and let it vent where it cannot cause damage.
An explosion venting panel has three main layers: a metal section calibrated according to the specific application, a protection base, and a PTFE holding membrane; where necessary, DonadonSDD can also supply venting panels with counterpressure support, or with an ATEX, EX II GD and EX II D certification.
Explosions: in industrial plants, a real and destructive danger, against which it is essential to find protection. Explosion venting panels are the ideal product for the job.
There are several possible applications and situations, in industrial plants, where it is necessary to protect the structure against a very concrete risk of explosion, usually due to the nature of the products being processed. Explosion venting panels are often the ideal solution to implement a measure of safety in points where this issue is critical, since they are built to yield against pressure as it rises, and let it vent where it cannot cause damage.
An explosion venting panel has three main layers: a metal section calibrated according to the specific application, a protection base, and a PTFE holding membrane; where necessary, DonadonSDD can also supply venting panels with counterpressure support, or with an ATEX, EX II GD and EX II D certification.
Model NAM 03/HT
Storage temperature From -40°C to +200°C in accordance with ATEX certification
Material in contact with process fluid Same as disc and disc holder
Max switching voltage 60 VDC
Max switching current 0,4 A
Cable 2 x 0.2 mm2,ø 3.4 mm, 200°C, Class C2
Degree of protection IP 67
Rupture disk DCD, DIF, LPD, SCD, SCR, Y90, KRD
Technical optical fibre properties
Model OFI 04 OFI 07
Optical fibre Plastic Glass with steel protection
Operating temperature From -55 to +70°C/+105°C From -40°C to +250°C
Minimum bending radius R25 R23
Technical amplifier properties
Model OFI 04 OFI 07
Amplifier supply power 12-24 VDC
Amplifier consumption 45 mA max
Operating temperature From -10°C to +60°C
Feedback time 1 msec
Degree of protection IP64
Amplifier material ABS
Rupture disk DCD, DIF, LPD, SCD, SCR, Y90, KRD
Model G-GA
Materials Graphite and Stainless steel
Dimensions DN 25 – DN 300
Rupture pressure 0.017 – 15 bar g (depending on diameter)
Tolerance from +/- 10 % to +/- 20%
Operating temperature from -60 °C to 300 °C
Operating margin up to 75%
Vacuum support Not Available
Fragmentation Yes
Use under valve No
Corrosion resistance Very good – can be protected with a PTFE membrane
Linings No
Container Included, mounted between flanges
Seals Available in graphite
Rupture sensor Electrical
PED Certification [CE STAMP] Available
Model G-GM
Materials Graphite
Dimensions DN 25 – DN 600
Rupture pressure 0.017 – 15 bar g (depending on diameter)
Tolerance from +/- 10 % to +/- 20%
Operating temperature from -60 °C to 180 °C
Operating margin up to 75%
Vacuum support Available
Fragmentation Yes
Use under valve No
Corrosion resistance Very good – can be protected with a PTFE membrane
Linings No
Container Included, mounted between flanges
Seals Available in graphite
Rupture sensor Electrical
PED Certification [CE STAMP] Available
Model G-GR
Materials Graphite
Dimensions DN 25 – DN 200
Rupture pressure 0.017 – 15 bar g (depending on diameter)
Tolerance from +/- 10 % to +/- 20%
Operating temperature from -60 °C to 180 °C
Operating margin up to 75%
Vacuum support Available
Fragmentation Yes
Use under valve No
Corrosion resistance Very good – can be protected with a PTFE membrane
Linings No
Container GR, HI/A
Seals Available in Graphite and Cork
Rupture sensor Electrical
PED Certification [CE STAMP] Available
Model SU/M
Materials Stainless steel
Dimensions from DN 3 to DN 40
Rupture pressure 20 – 1150 bar g (depending on material and diameter)
Tolerance from +/- 5 % to +/- 10%
Operating temperature Up to 480 °C
Operating margin 80%
Vacuum support No
Fragmentation Yes (Without fragmentation in special execution)
Use under valve No
Corrosion resistance Very good
Container Included, direct mounting
PED Certification [CE STAMP] Available
Model SU/T
Materials Stainless steel
Dimensions from DN 3 to DN 40
Rupture pressure 20 – 1150 bar g (depending on material and diameter)
Tolerance from +/- 5 % to +/- 10%
Operating temperature Up to 480 °C
Operating margin 80%
Vacuum support No
Fragmentation Yes (Without fragmentation in special execution)
Use under valve No
Corrosion resistance Very good
Container Included, direct mounting
PED Certification [CE STAMP] Available